Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy

Main Article Content

Ahmed Abed Mohammed Raed Ayad Abduljabbar

Abstract

Enhancement of the performance for hybrid solar air conditioning system was presented in this paper. The refrigerant temperature leaving the condenser was controlled using three-way valve, this valve was installed after the compressor to regulate refrigerant flow rate towards the solar system. A control system using data logger, sensors and computer was proposed to set the opening valve ratio. The function of control program using LabVIEW software is to obtain a minimum refrigerant temperature from the condenser outlet to enhance the overall COP of the unit by increasing the degree of subcooled refrigerant. A variable load electrical heater with coiled pipe was used instead of the solar collector and the storage tank to simulate the solar radiation.  Experimental data was measured to study the performance of the system. The proposed system was compared with the conventional one. Results show that the COP of the proposed system was higher than the COP of the conventional system by 10 %. In addition, the controlled system saved an electricity of 11.2 %. The optimum opening valve ratio fluctuated between 0.3 and 0.4 when the heater power was 500 W.


 

Article Details

How to Cite
MOHAMMED, Ahmed Abed; ABDULJABBAR, Raed Ayad. Enhancement of Hybrid Solar Air Conditioning System using a New Control Strategy. Al-Khwarizmi Engineering Journal, [S.l.], v. 14, n. 4, p. 24-33, dec. 2018. ISSN 2312-0789. Available at: <http://alkej.com/index.php/en/article/view/733>. Date accessed: 12 dec. 2018. doi: https://doi.org/10.22153/https://doi.org/10.22153/kej.2018.04.002.
Section
Articles

References

[1] H.M. Henning, Solar assisted air conditioning of buildings – an overview, Applied Thermal Engineering 27 (2006) 1734–1749.
[2] M.T. Evans, N. Kapur, J. Summers, H. Thompson, D. Oldham, an experimental and theoretical investigation of the extent of bypass air within data centres employing aisle containment, and its impact on power consumption, Applied Energy 186 (2016) 457-469.
[3] Q.P. Ha, V. Vakiloroaya, a novel solar-assisted air-conditioner system for energy savings with performance enhancement, Procardia Engineering 49 (2012) 116-123.
[4] V. Vakiloroaya, R. Ismail, Q.P. Ha, Development of a new energy-efficient hybrid solar-assisted air conditioning system, International Symposium on Automation and Robotics in Construction and Mining 30 (2013) 1424-1435.
[5] V. Vakiloroaya, Q.P. Ha, M. Skibniewski, Modeling and experimental validation of a solar-assisted direct expansion air conditioning system, Energy and Buildings 66 (2013) 524-536
[6] M.A. Abid, N.A. Jassim, Experimental evaluation of thermal performance of solar assisted air conditioning system under Iraq climate, Journal of Energy Technologies and Policy 5 (2015) 1-13.
[7] S. Kumar, D. Buddhi, H.K. Singh, Performance analysis of solar hybrid air-conditioning system with different operating conditions, Imperial Journal of Interdisciplinary Research 2 (2016) 1951-1956.
[8] H.M. Hussain, L.J. Habeeb, O.J. Abbas, Investigation on solar hybrid cooling system with high latent cooling load, Advances in Environmental Biology 11 (2017) 24-36.